Background and Aims:

Background:Pain relief is essential in post mastectomy patients. Reviewing literature, many drugs such as NSAIDS, anti-convulsants, anti-depressants, opioids and gabapentin have been used with limited success. Inadequate pain relief as an important factor in the development of post mastectomy pain syndromes. Male breast cancer accounts for less than 1% of breast cancers. 

Methods:

Patient was given bilateral PEC1-10ml and deep Serratus anterior block 25ml 0f 0.2% ropivacaine in combinations with Inj Tramadol 75mg i,v. and Inj Paracetamol 1gm i.v. after administering general anaesthesia.

Results:

Bilateral PEC1 and deep serratus anterior plane block with 0.2% Ropivacaine provided analgesia for 25 hours. VAS 0/1/2 at 12 hours, 20 hours and 25 hours respectively. Surgical field is also clear.

Conclusions:

Both blocks facilitated early recovery with good surgical field and rendered patient pain free and ambulatory within hours of surgery.

Code of conduct/disclaimer available in General Terms & Conditions
Anonymous User Privacy Preferences

Strictly Necessary Cookies (Always Active)

MULTILEARNING platforms and tools hereinafter referred as “MLG SOFTWARE” are provided to you as pure educational platforms/services requiring cookies to operate. In the case of the MLG SOFTWARE, cookies are essential for the Platform to function properly for the provision of education. If these cookies are disabled, a large subset of the functionality provided by the Platform will either be unavailable or cease to work as expected. The MLG SOFTWARE do not capture non-essential activities such as menu items and listings you click on or pages viewed.


Performance Cookies

Performance cookies are used to analyse how visitors use a website in order to provide a better user experience.



Google Analytics is used for user behavior tracking/reporting. Google Analytics works in parallel and independently from MLG’s features. Google Analytics relies on cookies and these cookies can be used by Google to track users across different platforms/services.


Save Settings